Estanda | IEC60947-2 |
Pòl No | 1P, 2P, 3P, 4P |
Rated Voltage | 1P:250V 2P:500V 3P:800V 4P:1000V |
Kouran nominal nan (A) | 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63, |
Koub Tripping | B, C |
Rated kout-sikwi kraze kapasite | 10kA |
Rated enpilsyon kenbe tèt ak vòltaj | 6.2KV |
Eletro-mekanik andirans | 10000 |
Tèminal vis | M5 |
Rated koupl | 2.0Nm |
Pwosedi tès la | Kalite | Tès aktyèl | Eta inisyal | Limit Tan pou Tripping oswa ki pa Peye | Rezilta espere | Remak |
A | B,C | 1.05 nan | frèt | t≥1h(In≤63A) t≥2h(In>63A) | pa gen okenn tripping | |
B | B,C | 1.3 nan | apre tès A | t<1h(In≤63A) t<2h(In>63A) | tripping | Aktyèl nan 5s yo nan ogmantasyon th nan estabilite |
C | B,C | 2 nan | frèt | 10s20s63A) | tripping | |
D | B | 4nan | frèt | t≤0.2s | pa gen okenn tripping | Limen switch oksilyè a |
E | C | 8nan | fèmen kouran an | |||
D | 6nan | frèt | t<0.2s | tripping | ||
B | 12 nan |